- Online double-conversion
- DSP technology guarantees high reliability
- True galvanic isolation transformer design
- Control designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adjustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units (option)
- Variety of communicatin options available
- Optional 7” touch LCD
- Reverse phase frequency operation and supports non-neutral input
Model | NIX- 33U010 | NIX- 33U015 | NIX- 33U020 | NIX- 33U030 | NIX- 33U040 | NIX- 33U060 | NIX- 33U080 | NIX- 33U100 | NIX- 33U120 | NIX- 33U160 | NIX- 33U200 |
Capacity | 10KVA/ 8KW | 15KVA/ 12KW | 20KVA/ 16KW | 30KVA/ 24KW | 40KVA/ 32KW | 60KVA/ 48KW | 80KVA/ 64KW | 100KVA/ 80KW | 120KVA/ 96KW | 160KVA/ 128KW | 200KVA/ 160KW |
INPUT | |||||||||||
Nominal Voltage | 3x 380VAC/400VAC (3Ph+N) | ||||||||||
Acceptable Voltage Range | 285VAC ̴ 475VAC | ||||||||||
Frequency | 50/60Hz ±10% | ||||||||||
INVERTER | |||||||||||
Nominal Voltage | 3x 380VAC/400VAC (3Ph+N) | ||||||||||
Precision | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) | ||||||||||
Frequency | 50/60Hz synchronised ±1% With mains absent ±0.1Hz | ||||||||||
Max. Syncrhronisation Speed | ±1Hz/s | ||||||||||
Waveform | Pure Sinewave | ||||||||||
Total Harmonic Distortion (THDv) | <2% (Linear load) ; <5% (Non-linear load) | ||||||||||
Phase Displacement | 120º ±1% (balanced load) ; 120º ±2% (imbalanced 50% of the load) | ||||||||||
Dynamic Recovery Time | 3 cycles at 90% of the static value | ||||||||||
Admissible Overload | 110% for 10min; 150% for 60sec; >160% fr 200ms | ||||||||||
Admissible Crest Factor | 3:1 | ||||||||||
Admissible Power Factor | 0.6 ̴ (inductive or capacitive) | ||||||||||
Imbalance Output Voltage @100% Unbalanced Load | <1% | ||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | ||||||||||
STATIC BYPASS | ||||
Type | Solid state | |||
Voltage | 3x 380VAC/400VAC (3Ph+N) | |||
Frequency | 50/60Hz | |||
Activation Criterion | Microprocessor control | |||
Transfer Time | Zero | |||
Admissible Overload | 150% for 1hour; 180% for 30sec; >200% for 200ms | |||
Transfer to Bypass | Immediate, for overloads above 160% | |||
Retransfer | Automatically retransfer after alarm is clear | |||
MAINTENANCE BYPASS | ||||
Type | Without interruption | |||
Voltage | 3x 400VAC (3Ph+N) | |||
Frequency | 50/60Hz | |||
Overall Line Mode Efficiency Battery Mode | 90% 90% | 91% 91% | 92% 93% | 93% 93% |
BATTERY & CHARGER | ||||
Battery Type & Numbers | 12VDC x32pcs (29 ̴ 32pcs adjustable) | |||
Nominal Battery Voltage | 384VDC (Based on 32pcs batteries) | |||
Charging Method | CC/CV | |||
Charging Current | Default 5A, Max current depends on lo | : ad level/ | Default: | 10A, Max: 40A |
Charging Voltage | 432VDC (Based on 32pcs batteries) | |||